Comparing CA-10 Anti Bedsore Air Mattress Options: Intended Use, Packaging and Documentation


Shijiazhuang Chuangen Technology Co.,Ltd.JOURNAL / SIDE BY SIDE

SIDE BY SIDE

Comparing CA-10 Anti Bedsore Air Mattress Options: Intended Use, Packaging and Documentation

Shijiazhuang Chuangen Technology Co.,Ltd. lists two CA-10 anti bedsore air mattress variants in its product catalogue. Both share alternating-pressure bubble cell technology and medical-grade PVC construction, but their published documentation differs in scope and detail. This comparison examines intended use statements, physical parameters, pump specifications, noise claims, packaging convenience features and documentation depth, helping procurement teams and distributors identify which listing best fits their sourcing or compliance needs.

Comparing CA-10 Anti Bedsore Air Mattress Options: Intended Use, Packaging and Documentation
AI-generated illustration; not a real product photograph, specification, operating permission or test certificate.
01

CA-10 Medical Anti-Bedsore Bubble Air Mattress (ref-1)

02

CA-10 Medical Device Inflatable Anti Bedsore Anti Decubitus Bubble air Mattress (ref-2)

Overview

An anti bedsore air mattress uses alternating pressure across a series of bubble air cells to redistribute body weight, reduce sustained tissue compression and help prevent pressure ulcers in long-term bedridden patients. Shijiazhuang Chuangen Technology Co.,Ltd. lists two CA-10 variants in its catalogue. Although they share a common design platform, their published documentation differs in scope, parameter detail and intended-use language — all of which matter when comparing product listings for importation, hospital procurement or regulatory submission.

This article compares the two variants strictly on the basis of confirmed published materials. Where a value is recorded for one variant but not the other, that gap is noted explicitly; no missing value is inferred or estimated.


The Two Subjects

Subject ASubject B
Product nameCA-10 Medical Anti-Bedsore Bubble Air MattressCA-10 Medical Device Inflatable Anti Bedsore Anti Decubitus Bubble air Mattress
Referenceref-1ref-2

Both products are manufactured by Shijiazhuang Chuangen Technology Co.,Ltd.


Criterion 1 — Intended Use Statement and Target Setting

Subject A does not publish an explicit intended-use narrative. Its listing focuses on technical features and pump specifications, positioning the product primarily through measurable parameters.

Subject B carries a detailed intended-use statement: "a professional medical device designed to effectively prevent pressure ulcers (bedsores) for long-term bedridden patients, elderly people, and those with limited mobility." It explicitly names three care settings — medical care, nursing homes and home care — and explains the alternating pressure mechanism in relation to blood circulation support and pressure redistribution.

Summary: Subject B provides broader and more explicitly stated intended-use language. Subject A relies on specification data rather than a narrative use statement.


Criterion 2 — Published Physical Dimensions and Load Capacity

ParameterSubject ASubject B
Mattress size2000 × 900 mm190 × 90 cm (1900 × 900 mm)
Load capacity135 kg135 kg
Number of bubble cells130Not stated
MaterialThickened medical PVCMedical-grade PVC

The two variants publish different nominal lengths (2000 mm vs. 1900 mm). Both values are drawn directly from confirmed source materials; the discrepancy should be verified with the manufacturer before quoting either figure in a procurement document. Load capacity is confirmed at 135 kg for both. Only Subject A states the bubble cell count (130).


Criterion 3 — Pump and Electrical Specifications

ParameterSubject ASubject B
Working voltageAC 220 V / 110 VNot separately tabulated
Frequency50 Hz / 60 HzNot stated
Power consumption10 WNot stated
Pressure range15–20 kPa (115–150 mmHg)Not stated
Air output4.5–5.5 L/minNot stated in pump table
Inflation flow rate≥6 L/min (feature list)>6 L/min (feature list)
Fluctuation cycle8–10 minutesNot separately tabulated

Subject A publishes a dedicated pump specification table covering voltage, frequency, power, pressure range, air output and cycle time. Subject B lists inflation flow rate in its feature bullets but does not publish a pump specification table. Buyers requiring detailed electrical documentation for regulatory submissions will find Subject A's listing more complete in this area.


Criterion 4 — Noise Level Claim

Subject A states: "Low noise design, not more than 20 dB."

Subject B states: "ultra-quiet air pump that operates at a low noise level (below 32 dB)."

Both variants publish a noise ceiling, but the published figures differ (≤20 dB vs. <32 dB). These are listing claims drawn from each product's own documentation; neither figure is independently verified in the approved materials. Buyers for whom acoustic performance in shared patient rooms is a key criterion should request test data from Shijiazhuang Chuangen Technology Co.,Ltd. before making a specification commitment.


Criterion 5 — Packaging Convenience and Storage Features

Subject A does not include packaging or storage language in its published listing.

Subject B documents storage convenience: "simply open the air valve, and it can be rapidly deflated, folded, and stored without taking up much space, making it easy to carry and store for home care, hospital transfers, or temporary use." This language directly addresses buyers evaluating logistics, storage space and portability — for example, distributors shipping to home-care or nursing-home markets.


Shared Features (Both Variants)

The following features appear in the confirmed documentation of both variants:

  • Cycle fluctuation + manual pump adjustment — alternating pressure combined with manual pressure control.
  • PVC thickened fabric — waterproof and breathable.
  • Dual-voltage compatibility — 220 V and 110 V (Subject A confirms 50/60 Hz frequency; Subject B references dual voltage in its feature list).
  • Inflation flow rate — both list ≥6 L/min or >6 L/min.
  • Waterproof, wipe-clean surface — confirmed for both.
  • 135 kg load capacity — confirmed for both.

Documentation Depth at a Glance

Documentation elementSubject ASubject B
Dedicated pump specification table✓—
Explicit intended-use narrative—✓
Named care settings—✓
Noise ceiling stated✓ (≤20 dB)✓ (<32 dB)
Number of air cells stated✓ (130)—
Storage and portability description—✓
Mattress size published✓ (2000 × 900 mm)✓ (190 × 90 cm)
Load capacity published✓ (135 kg)✓ (135 kg)

Buyer Guidance

  • For regulatory or technical dossiers requiring pump voltage, frequency, power consumption and pressure range: Subject A's listing provides a dedicated specification table.
  • For distributor catalogues or nursing-home procurement where plain-language description of medical purpose, care settings and user convenience is needed: Subject B's listing offers richer narrative documentation.
  • For logistics planning (transport, storage, space constraints): Subject B explicitly addresses deflation, folding and carry convenience.
  • For acoustic-sensitive environments: Both variants state a noise ceiling; independent test data is not included in the approved materials and should be requested separately from the manufacturer.

Both variants are produced by Shijiazhuang Chuangen Technology Co.,Ltd. under the CA-10 model designation. The differences described here are differences in published documentation, not independently verified differences in physical performance.


About Shijiazhuang Chuangen Technology Co.,Ltd.

Shijiazhuang Chuangen Technology Co.,Ltd. was established in 2019 and is engaged in the research, development, production and sales of health-care products for elderly and disabled users, including mattress series, electric wheelchair series, walker series and toilet chair series. The company has passed ISO 13485:2016 quality system certification and holds CE certification on selected products.

THE COMPANY

Shijiazhuang Chuangen Technology Co.,Ltd.

Shijiazhuang Chuangen Technology Co., Ltd. was established in 2019, after years of development, We have numbers of mature and professional modern intelligent industry lines, As well as high-tech equipment for welding and cutting production, a complete inspection and quality inspection system, and professional technical research personnel.At present, the company has passed ISO13485:2016 quality system certification, and some products have CE certification.etc.…

About Us ↗Visit company website ↗

YOUR NEXT STEP

Bring your brief. Start a useful conversation.

Use case, specification, quantity and delivery window: make the next conversation specific.

request a quote

Complete Control Over Products Allows Us To Ensure Our Customers Receive The Best Quality Prices And Service. We Take Great Pride In Everything That We Do In Chuangen Medical !

electric wheelchair factory

Leave Your Message

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.